Print Back
POLYPROPYLENE LOCKING COMBO® VALVE WITH SEPTUM
  • On/Off valve function with septum in a single unit is economical.
  • Lightweight, making it easier to carry in the field and reduces shipping costs.
  • Made of inert polypropylene to ensure purity of sample and non-contamination.
  • Push/Pull (On/Off) valve stem for quick, easy opening and closing of valve (< 1 second).
  • Faster than "twist action" valves.
  • Quick locking function, in closed position. Locked position is easy to verify visually, and prevents accidental sample loss during shipment
  • Virtually impossible to open or close valve too far
  • Valve Stem is 3/16" diameter
  • Fluoropolymer faced septum, with Ultra-low bleed silicone, prevents contamination and is located in base flange of valve with bag film below, so septum does not come into contact with sample inside bag.
  • Septum allows repeated punctures with syringes without leakage
  • Designed, Patented and Manufactured by Jensen Inert Products specifically for gas sampling applications.
  • Prices include Locking Combo® Valve with septum.
  • 3/16 OD stem for use with most 1/4" OD plastic and fluoropolymer tubing.
  • Bags with grommets available.
  • Bags with multiple fittings available.
  • Custom sized bags available.
Unit of Measure

Specifications

Film Material

N/A MULTI-LAYER FOIL

Capacity

N/A 9.5 L

Size

N/A 12 x 18 in

Film Thickness

N/A 0.0046 in

Bags Per Package

N/A 10

Valve Stem Diameter

N/A 3/16 in

Use with Tubing Size (ID)

N/A 3/16 in

Minimum Order Quantity

N/A 10

Note

N/A Valve is inert, industry standard polypropylene.
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I. Dupont

Valve/Fitting Features

N/A

  • On/Off valve function with septum in a single unit.
  • Lightweight.
  • Made of Inert polypropylene.
  • Push/Pull (On/Off) valve stem.
  • Quick Locking function, in closed position, with visual confirmation. No tools required.
  • Fluoropolymer faced septum, with Ultra-low bleed silicone.
  • Designed, patented and manufactured by Jensen Inert Products.

Film Key Features

N/A

  • Our Multi-Layer Foil bags are the best choice for collecting and storing H2S.
  • Ideal for sampling and storing for low molecular weight compounds such as Methane, CO, CO2, Hydrogen, and inert gases which are not stable in Tedlar®, ALTEF, or FEP.
  • Water and vapor proof, these opaque, flexible bags protect light sensitive compounds.
  • They provide up to 5 day sample stability for many VOCs, with minimal adsorption.

Suggestion

N/A

  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.

Film Properties

N/A

  • Ideal for collecting low molecular weight compounds such as: CH4, H2S, CO, and CO2
  • Foil layers provide very low permeability and complete moisture barrier
  • Maximum operating temperature: 190 ºF
  • Opaqueness protects samples from ultraviolet light

Film Advantages

N/A

  • The only bag material that adequately holds H2S for long periods (>5 to 7 days)
  • Ideal for collecting low molecular weight compounds
  • Sample stability for up to 5 days for most compounds
  • Very low permeability to O2, CO2
  • Good VOC stability
  • Less expensive than Tedlar® and ALTEF

Film Limitations

N/A

  • Not recommended for collecting low ppm to high ppb VOC's due to background levels from bag materials
  • Recommend analyzing within 48 hours after collection for methane, hydrogen sulfide, carbon monoxide and carbon dioxide

Valve/Fitting Benefits

N/A

  • Economical: Cost savings in manufacturing is passed on to customers.
  • Reduces shipping costs. Easier to carry multiple bags into the field.
  • Ensures purity of sample and non-contamination.
  • Quick, easy opening and closing of valve (< 1 second).
  • Faster than "twist-action" valves.
  • Locked position is easy to verify visually, and prevents accidental sample loss during shipment. Virtually impossible to open or close valve to far.
  • Located in base flange of valve with bag film below, so septum does not come into contact with sample inside bag. Septum allows repeated punctures with syringes without leakage. Ultra-low bleed silicone prevents contamination.
  • Designed specifically for gas sampling applications.