Print Back
SINGLE STAINLESS STEEL PUSH/PULL VALVE
  • Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
  • Push/Pull (On/Off) valve stem for quick, easy opening and closing of valve
  • Aluminum collar locked on SS valve body and nut
  • 3/16" diameter Stainless Steel stem
  • Prices include single Stainless Steel Push/Pull Valve
  • Bags with grommets available.
  • Bags with multiple fittings available.
  • Custom sized bags available.
Unit of Measure

Specifications

Film Material

N/A MULTI-LAYER FOIL

Capacity

N/A 12.0 L

Size

N/A 12 x 21 in

Film Thickness

N/A 0.0046 in

Bags Per Package

N/A 5

Valve Stem Diameter (OD)

N/A 3/16 mm

Use with Tubing Size (ID)

N/A 3/16 in

Minimum Order Quantity

N/A 5

Note

N/A Valve is Stainless Steel.
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I Dupont

Valve/Fitting Features

N/A

  • Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
  • Stainless Steel valve body and nut
  • 3/16" OD Stainless Steel stem
  • Thumbscrew to lock valve in open or closed position

Film Key Features

N/A

  • Our Multi-Layer Foil bags are the best choice for collecting and storing H2S.
  • Ideal for sampling and storing for low molecular weight compounds such as Methane, CO, CO2, Hydrogen, and inert gases which are not stable in Tedlar®, ALTEF, or FEP.
  • Water and vapor proof, these opaque, flexible bags protect light sensitive compounds.
  • They provide up to 5 day sample stability for many VOCs, with minimal adsorption.

Suggestion

N/A

  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.

Film Properties

N/A

  • Ideal for collecting low molecular weight compounds such as: CH4, H2S, CO, and CO2
  • Foil layers provide very low permeability and complete moisture barrier
  • Maximum operating temperature: 190 ºF
  • Opaqueness protects samples from ultraviolet light

Film Advantages

N/A

  • The only bag material that adequately holds H2S for long periods (>5 to 7 days)
  • Ideal for collecting low molecular weight compounds
  • Sample stability for up to 5 days for most compounds
  • Very low permeability to O2, CO2
  • Good VOC stability
  • Less expensive than Tedlar® and ALTEF

Film Limitations

N/A

  • Not recommended for collecting low ppm to high ppb VOC's due to background levels from bag materials
  • Recommend analyzing within 48 hours after collection for methane, hydrogen sulfide, carbon monoxide and carbon dioxide

Valve/Fitting Benefits

N/A

  • Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
  • Thumbscrew to lock valve in open or closed position
  • Sample contacts only Stainless Steel.