Print Back
STAINLESS STEEL SWAGELOK® TYPE FITTING FOR 1/4" OD TUBING
  • Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
  • Option of cap for tubing or septum, allows attachment of tubing or syringe sample extraction by switching caps
  • Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
  • Allows reuse of valve by only replacing septum
Stainless Steel Swagelok<sup>®</sup> Type Fitting for 1/4" O.D. Tubing
Unit of Measure
Items Stainless Steel Swagelok<sup>®</sup> Type Fitting for 1/4" O.D. Tubing
GSAS000-0606J
6 x 6 Inch (in) Size Multi-Layer Foil Gas Sampling Bag with Stainless Steel Swagelok® Type Fitting for 1/4" OD Tubing
Stainless Steel Swagelok<sup>®</sup> Type Fitting for 1/4" O.D. Tubing
GSAS000-0707J
7 x 7 Inch (in) Size Multi-Layer Foil Gas Sampling Bag with Stainless Steel Swagelok® Type Fitting for 1/4" OD Tubing
Stainless Steel Swagelok<sup>®</sup> Type Fitting for 1/4" O.D. Tubing
GSAS000-0610J
6 x 10 Inch (in) Size Multi-Layer Foil Gas Sampling Bag with Stainless Steel Swagelok® Type Fitting for 1/4" OD Tubing
Stainless Steel Swagelok<sup>®</sup> Type Fitting for 1/4" O.D. Tubing
GSAS000-0909J
9 x 9 Inch (in) Size Multi-Layer Foil Gas Sampling Bag with Stainless Steel Swagelok® Type Fitting for 1/4" OD Tubing
Stainless Steel Swagelok<sup>®</sup> Type Fitting for 1/4" O.D. Tubing
GSAS000-1010J
10 x 10 Inch (in) Size Multi-Layer Foil Gas Sampling Bag with Stainless Steel Swagelok® Type Fitting for 1/4" OD Tubing
Film Material N/A MULTI-LAYER FOIL
Capacity N/A 0.6 L N/A 1.0 L N/A 1.2 L N/A 2.0 L N/A 3.0 L
Size N/A 6 x 6 in N/A 7 x 7 in N/A 6 x 10 in N/A 9 x 9 in N/A 10 x 10 in
Film Thickness N/A 0.0046 in
Note N/A Valve is Stainless Steel.
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I Dupont
Bags Per Package N/A 5
Valve/Fitting Features N/A
  • Stainless steel construction.
  • Option of cap for tubing or septum.
  • Replaceable fluoropolymer faced septum with large area.
Film Key Features N/A
  • Our Multi-Layer Foil bags are the best choice for collecting and storing H2S.
  • Ideal for sampling and storing for low molecular weight compounds such as Methane, CO, CO2, Hydrogen, and inert gases which are not stable in Tedlar®, ALTEF, or FEP.
  • Water and vapor proof, these opaque, flexible bags protect light sensitive compounds.
  • They provide up to 5 day sample stability for many VOCs, with minimal adsorption.
Suggestion N/A
  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.
Film Properties N/A
  • Ideal for collecting low molecular weight compounds such as: CH4, H2S, CO, and CO2
  • Foil layers provide very low permeability and complete moisture barrier
  • Maximum operating temperature: 190 ºF
  • Opaqueness protects samples from ultraviolet light
Film Advantages N/A
  • The only bag material that adequately holds H2S for long periods (>5 to 7 days)
  • Ideal for collecting low molecular weight compounds
  • Sample stability for up to 5 days for most compounds
  • Very low permeability to O2, CO2
  • Good VOC stability
  • Less expensive than Tedlar® and ALTEF
Film Limitations N/A
  • Not recommended for collecting low ppm to high ppb VOC's due to background levels from bag materials
  • Recommend analyzing within 48 hours after collection for methane, hydrogen sulfide, carbon monoxide and carbon dioxide
Valve/Fitting Benefits N/A
  • Durable and able to withstand use in austere sampling conditions.
  • Allows attachment of tubing or syringe sample extraction by switching caps.
  • Allows repeated punctures with common lab syringes. Allows reuse of valve by only replacing septum.
Use with Tubing Size (OD) N/A 1/4 in
Minimum Order Quantity N/A 5