NICKEL PLATED HR® ON/OFF VALVE WITH 1/4" DIAMETER BARBED STEM AND SEPARATE PLASTIC JACO® FITTING WITH FLUOROPOLYMER FACED SEPTUM

You get the features of both the HR® Valve and the Jaco® Fitting on one bag

HR® Features:

  • Nickel Plated to resist damage from most aggressive chemicals
  • 1/4" Barbed Stem for attaching tubing, helps keep tubing in place
  • Leak resistant seal in closed position, prevents sample loss. However, when stem is not closed, sample air passes into the ambient air outside valve

Jaco® Features:

  • Polypropylene molded construction is inexpensive compared to metal fittings
  • Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
  • Allows reuse of valve by only replacing septum.
  • Option of cap with septum or cap with tubing, allows syringe sample extraction or attachment of tubing by changing caps.
  • Compression ferrule secures tubing onto fitting, which provides a superior grip compared to metal fittings.
  • Standard Jaco can be used with 1/4" tubing. Jaco for 1/2" and 3/8" tubing also available.
Unit of Measure
Items
Nickel Plated HR<sup>®</sup> ON/OFF Valve with 1/4" Diameter Barbed Stem & Separate Plastic 1/4" Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

6 x 6 Inch (in) Size ALTEF Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem & Separate 1/4" Plastic Jaco® Fitting with Fluoropolymer Faced Septum

Nickel Plated HR<sup>®</sup> ON/OFF Valve with 1/4" Diameter Barbed Stem & Separate Plastic 1/4" Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

7 x 7 Inch (in) Size ALTEF Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem & Separate 1/4" Plastic Jaco® Fitting with Fluoropolymer Faced Septum

Nickel Plated HR<sup>®</sup> ON/OFF Valve with 1/4" Diameter Barbed Stem & Separate Plastic 1/4" Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

6 x 10 Inch (in) Size ALTEF Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem & Separate 1/4" Plastic Jaco® Fitting with Fluoropolymer Faced Septum

Nickel Plated HR<sup>®</sup> ON/OFF Valve with 1/4" Diameter Barbed Stem & Separate Plastic 1/4" Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

9 x 9 Inch (in) Size ALTEF Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem & Separate 1/4" Plastic Jaco® Fitting with Fluoropolymer Faced Septum

Nickel Plated HR<sup>®</sup> ON/OFF Valve with 1/4" Diameter Barbed Stem & Separate Plastic 1/4" Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

10 x 10 Inch (in) Size ALTEF Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem & Separate 1/4" Plastic Jaco® Fitting with Fluoropolymer Faced Septum
Film Material N/A ALTEF
Size N/A 6 x 6 in N/A 7 x 7 in N/A 6 x 10 in N/A 9 x 9 in N/A 10 x 10 in
Capacity N/A 0.6 L N/A 1.0 L N/A 1.2 L N/A 2.0 L N/A 3.0 L
Note N/A

HR® Valve is Nickel Plated and Jaco Fitting is inert, industry standard polypropylene.
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I. Dupont

Additional Information N/A
  • Catalog No. CAP-14-JT, Cap, Polypropylene, Jaco® Set Up for 1/4" Tubing
  • Catalog No. SEP5007-JSF-10, Septa, 10/90, 10 mm for Jaco Fitting/10 EA.
Valve Stem Diameter N/A 1/4 in Barbed
Valve/Fitting Features N/A
  • Compression ferrule secures tubing onto fitting.
  • Polypropylene molded construction.
  • Option of cap for tubing, or cap with septum.
  • Replaceable fluoropolymer faced septum with large area.
  • Nickel Plated
  • Barbed stem for attaching tubing.
  • Leak resistant seal in closed position.
Film Key Features N/A
  • ALTEF is a proprietary fluoropolymer film developed specially for the air sampling market.
  • ALTEF meets or exceeds many of the desired characteristics of Tedlar®.
  • Unlike Tedlar®, ALTEF does not exhibit background levels of DMAC and phenol.
  • ALTEFexhibits similar stability properties as Tedlar® for a wide variety of compounds, including most VOCs.
  • Low VOC and sulfur background levels.
  • Contains no additives, fillers or pigments.
  • Minimal adsorption.
  • Superior storage for organics.
  • Abrasion Resistant.
Suggestion N/A
  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.
Film Properties N/A
  • Developed specifically for gas sampling applications
  • Chemically inert to most acids, aliphatic and aromatic organic compounds, chlorinated solvents, and alcohols
  • Maximum operating temp: 260 ºF
  • ALTEF bags are made of 0.003" thick film.
  • Tensile Strength 6100 psi
Use with Tubing Size (OD) N/A 1/4 in
Film Advantages N/A
  • Suitable for sampling most VOCs and many sulfur compounds
  • Low VOC background
  • Longer sample storage times than most other bag materials
  • Does not exhibit background levels of DMAC or phenol, as Tedlar® does
  • Lower permeability than Tedlar® to CO2, N2, CH4
  • Superior resistance to solvents
Film Limitations N/A
  • More permeable to most compounds than Tedlar® (0.003" thick versus 0.002" for Tedlar® Bags)
  • Not suitable for sampling ketones and esters in high concentrations (>30 %)
  • Less resistance to UV light than Tedlar®
  • Many sulfur compounds should be analyzed within 24 hours.
  • More expensive than Tedlar®
Valve/Fitting Benefits N/A
  • Superior grip compared to metal fittings.
  • Inexpensive compared to metal fittings.
  • Allows attachment of tubing or syringe sample extraction by changing caps.
  • Allows repeated punctures with common lab syringes.
  • Allows reuse of valve by only replacing septum.
  • Resists damage from most aggressive chemicals.
  • Helps hold tubing in place.
  • Prevents sample loss in closed position. However, when stem is not closed, sample air passes into ambient air outside valve.
Minimum Order Quantity N/A 10
Bags Per Package N/A 10