POLYPROPYLENE SCREW CAP COMBO VALVE WITH REPLACEABLE SEPTUM

  • On/Off valve function with a replaceable septum in a single unit is economical.
  • Lightweight, making it easier to carry in the field and reduces shipping costs.
  • Made of inert polypropylene to ensure purity of sample and non-contamination.
  • Quick, easy opening and closing of valve to save time.
  • Cap stop limits amount cap can be opened to stop leaks from opening cap too far.
  • Visual confirmation that valve is open or closed, prevents accident sample loss.
  • No guessing whether valve is open or closed.
  • Valve Stem is 3/16" OD with tapered outer end for tubing or compression fitting.
  • Replaceable fluoropolymer faced, low bleed septum; allows reuse of valve by replacing inexpensive septum.
  • Designed and Manufactured by Jensen Inert Products specifically for gas sampling applications.
Unit of Measure
Items
Screw Cap Combo Valve<sup>®</sup> with Septum

6 x 6 Inch (in) Size ALTEF Gas Sampling Bag with Screw Cap Combo Valve® with Septum

Screw Cap Combo Valve<sup>®</sup> with Septum

7 x 7 Inch (in) Size ALTEF Gas Sampling Bag with Screw Cap Combo Valve® with Septum

Screw Cap Combo Valve<sup>®</sup> with Septum

6 x 10 Inch (in) Size ALTEF Gas Sampling Bag with Screw Cap Combo Valve® with Septum

Screw Cap Combo Valve<sup>®</sup> with Septum

9 x 9 Inch (in) Size ALTEF Gas Sampling Bag with Screw Cap Combo Valve® with Septum

Screw Cap Combo Valve<sup>®</sup> with Septum

10 x 10 Inch (in) Size ALTEF Gas Sampling Bag with Screw Cap Combo Valve® with Septum
Film Material N/A ALTEF
Capacity N/A 0.6 L N/A 1.0 L N/A 1.2 L N/A 2.0 L N/A 3.0 L
Size N/A 6 x 6 in N/A 7 x 7 in N/A 6 x 10 in N/A 9 x 9 in N/A 10 x 10 in
Film Thickness N/A 0.003 in
Note N/A

Valve is inert, industry standard polypropylene.
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I. Dupont

Bags Per Package N/A 10
Additional Information N/A

Catalog Number: SEP5007NSCV7010, Fluoropolymer Faced 0.070" Thick Septa, For Screw Cap Valve/10

Valve Stem Diameter N/A 3/16 in
Valve/Fitting Features N/A
  • On/off valve function with replaceable septum in a single unit.
  • Lightweight.
  • Made of Inert polypropylene.
  • Quick turning screw cap to open and close valve. Cap stop limits amount cap can be opened.
  • Visual confirmation that valve is open or closed.
  • Replaceable fluoropolymer faced, low bleed septum.
  • Designed and manufactured by Jensen Inert Products.
Film Key Features N/A
  • ALTEF is a proprietary fluoropolymer film developed specially for the air sampling market.
  • ALTEF meets or exceeds many of the desired characteristics of Tedlar®.
  • Unlike Tedlar®, ALTEF does not exhibit background levels of DMAC and phenol.
  • ALTEFexhibits similar stability properties as Tedlar® for a wide variety of compounds, including most VOCs.
  • Low VOC and sulfur background levels.
  • Contains no additives, fillers or pigments.
  • Minimal adsorption.
  • Superior storage for organics.
  • Abrasion Resistant.
Suggestion N/A
  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.
Film Properties N/A
  • Developed specifically for gas sampling applications
  • Chemically inert to most acids, aliphatic and aromatic organic compounds, chlorinated solvents, and alcohols
  • Maximum operating temp: 260 ºF
  • ALTEF bags are made of 0.003" thick film.
  • Tensile Strength 6100 psi
Film Advantages N/A
  • Suitable for sampling most VOCs and many sulfur compounds
  • Low VOC background
  • Longer sample storage times than most other bag materials
  • Does not exhibit background levels of DMAC or phenol, as Tedlar® does
  • Lower permeability than Tedlar® to CO2, N2, CH4
  • Superior resistance to solvents
Film Limitations N/A
  • More permeable to most compounds than Tedlar® (0.003" thick versus 0.002" for Tedlar® Bags)
  • Not suitable for sampling ketones and esters in high concentrations (>30 %)
  • Less resistance to UV light than Tedlar®
  • Many sulfur compounds should be analyzed within 24 hours.
  • More expensive than Tedlar®
Valve/Fitting Benefits N/A
  • Economical: Cost savings in manufacturing is passed on to customers. Septum can be changed.
  • Reduces shipping costs. Easier to carry in the field.
  • Ensures purity of sample and non-contamination.
  • Quick, easy opening and closing of valve: saves time. Cap stop leaks from opening cap too far.
  • Prevents accidental sample loss. No guessing whether valve is open or closed.
  • Allows reuse of valve by replacing inexpensive septum.
  • Designed specifically for gas sampling applications.
  • Economical: Cost savings in manufacturing is passed on to customers.
  • Reduces shipping costs. Easier to carry multiple bags into the field.
  • Ensures purity of sample and non contamination.
  • Quick, easy opening and closing of valve (< 1 second).
  • Faster than "twist action" valves.
  • Locked position is easy to verify visually, and prevents accidental sample loss during shipment. Virtually impossible to open or close valve to far.
  • Septum does not come into contact with sample inside bag. Septum allows repeated punctures with syringes without leakage. Ultra low bleed silicone prevents contamination.
  • Designed specifically for gas sampling applications.
Minimum Order Quantity N/A 10