PLASTIC JACO® Fitting for 3/8" Tubing or Septum
  • Polypropylene molded construction is inexpensive compared to metal fittings.
  • Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
  • Allows reuse of valve by only replacing septum.
  • Option of cap with septum or cap for use with tubing.
  • Allows syringe sample extraction or attachment of tubing by changing caps
  • Compression ferrule secures tubing onto fitting, which provides a superior grip compared to metal fittings
  • Prices include Jaco fitting for 3/8" OD tubing or septum.
  • Bags with grommets available.
  • Bags with multiple fittings available.
  • Custom sized bags available.
Unit of Measure
Items
3/8" Plastic Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

6 x 6 Inch (in) Size FEP Gas Sampling Bag with 3/8" Plastic Jaco® Fitting with Fluoropolymer Faced Septum

3/8" Plastic Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

7 x 7 Inch (in) Size FEP Gas Sampling Bag with 3/8" Plastic Jaco® Fitting with Fluoropolymer Faced Septum

3/8" Plastic Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

6 x 10 Inch (in) Size FEP Gas Sampling Bag with 3/8" Plastic Jaco® Fitting with Fluoropolymer Faced Septum

3/8" Plastic Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

9 x 9 Inch (in) Size FEP Gas Sampling Bag with 3/8" Plastic Jaco® Fitting with Fluoropolymer Faced Septum

3/8" Plastic Jaco<sup>®</sup> Fitting with Fluoropolymer Faced Septum

10 x 10 Inch (in) Size FEP Gas Sampling Bag with 3/8" Plastic Jaco® Fitting with Fluoropolymer Faced Septum
Description N/A PLASTIC JACO® Fitting for 3/8" Tubing or Septum
  • Polypropylene molded construction is inexpensive compared to metal fittings.
  • Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
  • Allows reuse of valve by only replacing septum.
  • Option of cap with septum or cap for use with tubing.
  • Allows syringe sample extraction or attachment of tubing by changing caps
  • Compression ferrule secures tubing onto fitting, which provides a superior grip compared to metal fittings
  • Prices include Jaco® fitting for 3/8" OD tubing or septum.
  • Bags with grommets available.
  • Bags with multiple fittings available.
  • Custom sized bags available.
Brands N/A PLASTIC JACO®
Film Material N/A Fluorinated Ethylene Propylene (FEP) Fluoropolymer
Capacity N/A 0.6 L N/A 1.0 L N/A 1.2 L N/A 2.0 L N/A 3.0 L
Size N/A 6 x 6 in N/A 7 x 7 in N/A 6 x 10 in N/A 9 x 9 in N/A 10 x 10 in
Film Thickness N/A 0.005 in
Note N/A Fitting is inert, industry standard polypropylene.
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I. Dupont.
Bags Per Package N/A 10
Additional Information N/A
  • Catalog No. CAP-38-JT, Cap, Polypropylene, Jaco® Set Up for 3/8" Tubing
  • Catalog No. SEP5007-38JSF-10, Replacement SEPTA for Jaco Fitting Pack of 10
Valve/Fitting Features N/A
  • Compression ferrule secures tubing onto fitting.
  • Polypropylene molded construction.
  • Option of cap for tubing, or cap with septum.
  • Replaceable fluoropolymer faced septum with large area.
Film Key Features N/A FEP is one of the most chemically inert materials for making gas sampling bags. It works well in extreme temperatures ranging from -400 to 400 ºF; allowing it to be used in most stack sampling conditions. 5 mil FEP film is completely resistant to the most severe corrosives. Much more permeable than Multi-Layer or Tedlar®. FEP bags can be specified for applications involving corrosive gases.
Suggestion N/A
  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.
Film Properties N/A
  • One of the most chemically inert materials available for making gas sampling bags
  • Maximum operating temperature: 400 ºF
  • Virtually transparent
Film Advantages N/A
  • Works well in extreme temperatures ranging from -400 to 400 ºF; allowing it to be used in all stack sampling conditions
  • Heavier gauge (0.005) film is resistant to most severe corrosives as well as tolerates applications involving rough handling or difficult service conditions
  • Less expensive than PFA
Film Limitations N/A
  • Poor long term storage stability for most VOC's and sulfur compounds
  • Much more permeable than Tedlar®, ALTEF, and Multi-Layer Foil bags
  • More expensive than Tedlar®, ALTEF, Multi-Layer Foil, and TFM bags
  • Lower tensile strength than Tedlar®
Valve/Fitting Benefits N/A
  • Superior grip compared to metal fittings.
  • Inexpensive compared to metal fittings.
  • Allows attachment of tubing or syringe sample extraction by changing caps.
  • Allows repeated punctures with common lab syringes.
  • Allows reuse of valve by only replacing septum.
Use with Tubing Size (OD) N/A 3/8 in
Minimum Order Quantity N/A 10
Intended Application N/A Sampling
Bag Type N/A Compression
Material Handled / Stored N/A Gas