• User begins by blowing/exhaling into the mouthpiece while opening the valve, by easily pushing the stem inward, toward the bag
  • To close the valve, the user pushes the collection bag outward with their free hand, which causes the stem to pull outward, into its closed position
  • Breath sample is collected and valve is locked into its closed position to eliminate any loss during transportTo extract breath sample for testing, the lab can either:
  • Insert syringe needle through base mounted septum
  • Insert Luer connector end of syringe (available upon request) into open end of mouthpiece, creating airtight connection.
Unit of Measure
Items
Tedlar® Breath Collection Bags

6 x 6 Inch (in) Size ALTEF Breath Collection Bags

Tedlar® Breath Collection Bags

6 x 10 Inch (in) SizeALTEF Breath Collection Bags

Tedlar® Breath Collection Bags

7 x 7 Inch (in) Size ALTEF Breath Collection Bags

Tedlar® Breath Collection Bags

7 x 7 Inch (in) Size ALTEF Breath Collection Bags
Description N/A 0.6 Liter Capacity
  • User begins by blowing/exhaling into the mouthpiece while opening the valve, by easily pushing the stem inward, toward the bag
  • To close the valve, the user pushes the collection bag outward with their free hand, which causes the stem to pull outward, into its closed position
  • Breath sample is collected and valve is locked into its closed position to eliminate any loss during transportTo extract breath sample for testing, the lab can either:
  1. Insert syringe needle through base mounted septum
  2. Insert Luer connector end of syringe (available upon request) into open end of mouthpiece, creating airtight connection.
N/A 1.2 Liter Capacity
  • User begins by blowing/exhaling into the mouthpiece while opening the valve, by easily pushing the stem inward, toward the bag
  • To close the valve, the user pushes the collection bag outward with their free hand, which causes the stem to pull outward, into its closed position
  • Breath sample is collected and valve is locked into its closed position to eliminate any loss during transportTo extract breath sample for testing, the lab can either:
  1. Insert syringe needle through base mounted septum
  2. Insert Luer connector end of syringe (available upon request) into open end of mouthpiece, creating airtight connection.
N/A 1 Liter Capacity
  • User begins by blowing/exhaling into the mouthpiece while opening the valve, by easily pushing the stem inward, toward the bag
  • To close the valve, the user pushes the collection bag outward with their free hand, which causes the stem to pull outward, into its closed position
  • Breath sample is collected and valve is locked into its closed position to eliminate any loss during transportTo extract breath sample for testing, the lab can either:
  1. Insert syringe needle through base mounted septum
  2. Insert Luer connector end of syringe (available upon request) into open end of mouthpiece, creating airtight connection.
N/A 1 Liter Capacity with Extra Material for Label
  • User begins by blowing/exhaling into the mouthpiece while opening the valve, by easily pushing the stem inward, toward the bag
  • To close the valve, the user pushes the collection bag outward with their free hand, which causes the stem to pull outward, into its closed position
  • Breath sample is collected and valve is locked into its closed position to eliminate any loss during transportTo extract breath sample for testing, the lab can either:
  1. Insert syringe needle through base mounted septum
  2. Insert Luer connector end of syringe (available upon request) into open end of mouthpiece, creating airtight connection.
Capacity N/A 0.6 L N/A 1.2 L N/A 1 L N/A 1 L
Note N/A Can be made in various capacites and sizes